Sun Microsystems SL500 User Manual

Page of 436
Library Firmware Upgrades
96116 • Revision: KA
Chapter 7 SL Console Diagnostics and Utilities 251
Library Firmware Upgrades
Note – 
This feature is available starting with SL500 firmware version 1022. 
The library firmware resides on the library controller. The initial firmware is installed 
at the factory. When new firmware is released, you must use the code load utility to 
upgrade the firmware on the library and associated devices (CAP and HandBot). 
Note – 
Library firmware does not contain drive code upgrades.   
Firmware Download Sites
The SL500 library firmware package is a .img (image) file. See 
 for download sites. 
Note – 
You must have a valid login ID and password for the download site you are 
using. Contact your Sun support representative for assistance. 
Firmware Installation Process
The process for loading firmware code on the library controller is as follows: 
1. Locate the firmware upgrade package (.img file) on the appropriate Sun download 
site. See 
2.  Download the code to a folder on your local PC or workstation. 
3.  Download the firmware package from your PC to the library controller. This process 
also unpacks the package after downloading to make it ready for activation. See 
4.  Activate the downloaded code on the library controller. See 
5.  Reboot the library to make the code operational. See