Sun Microsystems SL500 User Manual

Page of 436
Specifications
96116 • Revision: KA
Appendix A SL500 Wall Diagrams and Specifications 345
Library Component Weights
The following table lists the weights of the library, tape drives and trays, and 
cartridges.
Library Environment
The following table lists the library environment specifications.
TABLE A-2 Library Component Weights
Component
Weight 
Base module with 1 power supply, 2 LTO tape drives, and robotics unit
44.5 kg (98.0 lb)
Drive expansion module (DEM) with one power supply and four LTO 
tape drives
41.3 kg (91.0 lb)
Cartridge expansion module (CEM)
20.1 kg (44.2 lb)
Robotics unit
10.1 kg (22.2 lb)
Power supply
2.3 kg (5.1 lb)
HP LTO Ultrium tape drive and tray assy
3.6 kg (7.9 lb)
IBM LTO Ultrium tape drive and tray assy
4.5 kg (9.9 lb)
SDLT LVD tape drive and tray assy
4.2 kg (9.3 lb)
SDLT FC tape drive and tray assy
4.1 kg (9.0 lb)
DLT-S4 tape drive and tray assy
3.88 kg (8.6 lb)
Tape drive tray assy without tape drive
1.5 kg (3.4 lb)
LTO Ultrium cartridge
221.0 g (7.8 oz)
TABLE A-3 Library Environment Specifications
Item
Measurements
Operating
Storage
Transporting
Temperature
+10 to +40ºC
(+50 to +104ºF)
+10 to +40ºC
(+50 to +104ºF)
-40 to +60ºC
(-40 to +140ºF)
Humidity
20 to 80%
10 to 95%
10 to 95%
Wet bulb (maximum, 
noncondensing)
+29.2ºC
(+84.5ºF)
+35ºC
(+95ºF)
+35ºC
(+95ºF)
Altitude
-76 to 3,048 m (-250 to 10,000 ft)