Cartridge Access Ports
18 SL500 User’s Guide • July 2008
Revision: KA • 96116
Cartridge Access Ports
The cartridge access ports (CAPs) can be used to add cartridges to the library, or 
remove cartridges from the library without interrupting normal robotic operation. 
The CAP in the Base Module has one five-cell magazine. 
The CAP in the Drive Expansion Module has two five-cell magazines. 
Although the CAPs are not physically connected, they are logically connected. If any of 
the CAPs are open, the CAP LED on the keypad will be on, alerting the operator to take 
action to close the CAP. If all of the CAPs are closed, the CAP LED will be off.
You can use the keypad on the robotics unit to issue a command for the robot to unlock 
the CAP. 
The CAP has two settings, ALLOW and PREVENT. ALLOW is the default setting after 
you power-on or reset the library. The following table shows how these settings affect 
the CAPs. For CAP LED indicator information see 
.
CAP Condition
ALLOW
PREVENT
All of the CAPs are closed
When you press the CAP button 
all of the CAPs in the rack will 
open.
The library firmware turns on 
the CAP LED.
When you press the CAP 
button, the action is ignored and 
all of the CAPs remain closed.
Any of the CAPs are open
When you press the CAP 
button, any CAP that is not 
open in the rack will open.
When you press the CAP 
button, the action is ignored and 
all of the CAPs remain in their 
individual current state of open 
or closed.