Sun Microsystems SL500 User Manual

Page of 436
 
Interfaces
24 SL500 User’s Guide • July 2008
Revision: KA • 96116
Interfaces
The major interfaces are:
Library control path support for LVD SCSI or SCSI over Fibre Channel
Data path for a single-port SCSI or dual-port Fibre Channel tape drive
Cartridge access ports and sensors for indicating a door open or closed condition
Front door opened button (on keypad), key for opening door, sensor LED that 
indicates door is closed and latched.
Public 100BaseT Ethernet Port for the StorageTek Library Console (SL Console) and 
remote service access (see 
 an
). 
Note – 
Currently, only one RLC card is available.
FIGURE 1-6 Library Interfaces Locations
1. Private Ethernet port is for future use.
2. Eject OK (hot-swappable) LED, when on, indicates that the RLC card can be removed. (See 
note below.)
3. Public Ethernet port is for remote service access, SL Console, and SNMP (future)
4. Fault LED indicates that the controller has detected a problem.
5. Reserved for future use.
6. Standby LED, when lit, indicates the RLC card (when two RLC cards are installed) is in 
standby mode.
(See note below.)
7. CLI port is an RJ-45 serial port for service representatives.
8. Active LED, when lit, indicates this RLC card is active if two RLC cards are installed. If only 
one card is installed, the LED is always on. (See note below.)
PRIVATE
PUBLIC
RESERVED
CLI
EJECT
OK
FAULT
STANDBY
ACTIVE
L204_008
1
2
3
4
5
6
7
8