LaserSpeed 8000-3 Instruction Handbook
 
Interfacing with the LS8000-3 
 
 
Part No. 93463 / Drawing No. 0921-01561 
Page 84 of 221 
Revision A (Sep 2007) 
Domino A Series 
 
 
 
 
Pinout 
Signal 
Domino A200 
LaserSpeed 
Signal A 
15 
Print Go 
22 
Signal Ground 
11 
User Voltage 
20 
 
Notes: 
  Configure the LaserSpeed for the appropriate pulse per unit length. 
The index pulse should be set to trigger at the appropriate rate (every 2 
feet, every 1 meter, etc), and with a 20 ms pulse width.   
  On the Domino A-Series printer, the Strobe Divide should be set to 1. 
  There are two ports that are in parallel so it doesn’t matter which one is 
used. The other port would not be used. The printer should be set for 
EXTERNAL print and the REPEAT PRINTING should be turned off.