M o t i o n   C o m m a n d s
ACCEL
The ACCEL statement sets the axis acceleration for subsequent moves 
and remains in effect in a given program unless changed. Note: If a 
move instruction is executed before ACCEL, the tag Acceleration is 
used.
BLOCK NUMBER
Block numbers may be used as the destination of JUMP commands. 
Block numbers must be unique and can be between 1 and 65535. 
CAM
The CAM statement starts CAM motion and specifies exit conditions.
CAM-LOAD
CAM-LOAD loads a parameter register with the starting location for a 
CAM slave axis.
CAM-PHASE
CAM-PHASE sets the phase for CAM commands.
CALL
The CALL command executes another block as a subroutine
CMOVE
The CMOVE command programs a continuous move using the specified 
position and acceleration mode.
DWELL
DWELL causes motion to cease for a specified time period before 
processing the next command. 
ENDPROG
The ENDPROG statement terminates a PLC Motion program definition.
ENDSUB
The ENDSUB statement terminates a PLC Motion subroutine definition.
JUMP
Jump to a block number or a sync block within the current program or 
subroutine. The jump may be unconditional or conditional based on the 
status of a CTL bit. 
LOAD
Initializes or changes a parameter data register with a 32-bit twos-
complement integer value.
PMOVE
The PMOVE command programs a positioning move using the specified 
position and accelerator mode. 
PROGRAM
The PROGRAM statement is the first statement in a motion program. The 
program statement identifies the program number (1-10) and the axis 
configuration. Program definitions cannot nest. 
SUBROUTINE
The SUBROUTINE statement is the first statement in a motion 
subroutine. The subroutine statement identifies the subroutine number 
(1-40) and the axis configuration.
SYNC BLOCK
A sync block is a special case of a block number. A sync block may only 
be used in multi-axis programs.
VELOC
Sets the process VELOCITY used by subsequent motion program move 
commands and remains in effect until changed by another VELOC 