W o r k i n g   w i t h   t h e   L D   E d i t o r   O n l i n e
In online mode, there is a live communication connection to the target PLC 
enabling increased interaction with Logic Developer - PLC. 
While online, the LD editor animates the LD logic to reflect program execution in 
the target PLC. Data values change in real time while coils and contacts indicate 
power flow. Many GE Fanuc targets also supports Run Mode Store (RMS), that is, 
they support the downloading of logic to a running target.
Three methods are at your disposal to make changes in your LD logic and 
download the changes to an online running PLC:
Online Editing (PACSystems™ only): While you make your changes in your 
logic, the LD editor displays both the original logic and the modified logic, and 
the PACSystems™ executes the original logic. You can test your changes online, 
and the PACSystems™ retains an inactive copy of the original logic while 
executing the modified logic. You can then commit the modified logic 
permanently to the PACSystems™, or make the PACSystems™ revert back to 
the original logic, or cancel the test and continue editing the logic before testing 
the logic again or abandoning the modified logic.
Word-for-word changes: Changes in the logic made while online that fit in the 
same amount of memory as the original logic. For example, changing an 
operand is usually a word-for-word change. You can make a word-for-word 
change and download it to the PLC while online without having to download 
all the logic.
Other logic changes: Changes in the logic that do not fit in the same amount of 
memory as the original logic, for example, adding a new function in a rung or 
adding a new rung. Once you have completed a change, you can write the 
modified logic to the PLC while it is still running. (For some types of changes, 
you must stop the PLC and then download to it.)
To  go  o nli ne to  a  t ar g et P LC
In the 
 Project tab of the 
 Navigator, right-click the 
Target and choose Go Online
The grey target icon turns green to indicate that it is online. The status bar is 
updated to reflect the online status. The LD editor, if equal to the PLC, displays 
various online features, as shown in the following illustration: