CAUTION: Protective Earthing 
The equipment is classified as Class I EN60950 and UL60950 and must be 
earthed at all times. Units providing power sockets with three pins must be 
connected by service personnel to a socket-outlet with a protective earthing 
connection. 
To cable the V6000, follow these 3 steps: 
1  The V6000 must be permanently earthed using an equipment-earthing conductor. 
Connect an electrically earthed strap of 16 AWG wire (minimum) to the chassis earthing 
screw, using the supplied washer. The connection to the protective earthing should be in 
accordance with the regulations enforced in the country of installation. 
2  Connect the first Ethernet connection (labeled I), located on the CPU module of the 
V6000 front panel, directly to the network using a standard RJ-45 Ethernet cable. 
 
 
When assigning an IP address to the V6000 using HTTP (under 
Assigning an 
IP Address Using HTTP
), you may be required to disconnect this cable and re-
cable it differently. 
3  Connect the left (active) 100-240V~50-60 Hz power socket to the mains using the 
supplied cord. 
 
After connecting the V6000 to the power source, the power LED on the front panel of the 
power supply unit is lit green (after a self-testing period of about 2 minutes).