Nortel Networks 311 User Manual

Page of 1134
Electrical specifications
273
Table 112
LEI card - line interface unit electrical characteristics
Characteristics
Description
Framing
CRC-4 or FAS, only
Coding
AMI or HDB3
Signaling
Loop or ground start A/B robbed-bit
Distance to LTU
0-199.6 meters (0-655 feet)
Power requirements
shows the voltage and
maximum current that the LEI requires from the backplane. One NT8D06
IPE Power Supply AC or NT6D40 IPE Supply DC can supply power to
a maximum of eight LEIs.
Table 113
LEI card - power required
Voltage
Max. Current
5.0 V dc
1.6 Amp
+15.0 V dc
150 mA
-15.0 V dc
150 mA
Foreign and surge voltage protections
In-circuit protection against power line crosses or lightning strikes is not
provided on the LEI. It does, however, protect against accidental shorts to
–52 V dc analog lines.
When the card is used to service off-premise terminal equipment through
the public telephone network, install a Line Termination Unit (LTU) as part of
the terminal equipment to provide external line protection.
Environmental specifications
shows the
environmental specifications of the LEI.
Table 114
LEI card - environmental specifications
Parameter
Specifications
Operating temperature – normal
15

to +30

C (+59

to 86

F), ambient
Operating temperature – short term
10

to +45

C (+50 to 113

F), ambient
Operating humidity – normal
20% to 55% RH (non-condensing)
Operating humidity – short term
20% to 80% RH (non condensing)
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008