Nortel Networks 311 User Manual

Page of 1134
934
NTAK79 2.0 Mb PRI card
The main functional blocks of the NTAK79 architecture include:
DS-30X interface
A07 signaling interface
digital pad
carrier interface
CEPT transceiver
SLIP control
D-Channel support interface
8031 microcontroller
Card-LAN / echo / test port interface
A description of each block follows.
The main functional blocks of the NTAK79 architecture include:
DS-30X interface
A07 signaling interface
digital pad
carrier interface
CEPT transceiver
SLIP control
D-channel support interface
8031 microcontroller
Card-LAN / echo / test port interface
DS-30X interface
The NTAK79 interfaces to one DS-30X bus which contains 32
byte-interleaved timeslots operating at 2.56 Mb. Each timeslot contains 10
bits in A10 message format; eight are assigned to voice/data (64 kbps), one
to signaling (8 kbps), and one is a data valid bit (8 kbps).
The incoming serial bit stream is converted to 8-bit parallel bytes to be
directed to padding control.
The signaling bits are extracted and inserted by the A07 signaling interface
circuitry. The DS-30X timeslot number is mapped to the PCM-30 channel
number. Timeslots 0 and 16 are currently unused for PCM.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.