2.5 Returns/Service 
Before returning any equipment for service, you must obtain a Return Material 
Authorization (RMA) number from SBE: 
 
TEL: 800-925-2666 (Toll free, USA) 
 
TEL: +925-355-2000 (Outside of USA) 
 FAX: 
+925-355-2020 
Ship all returns to SBE’s USA service center: 
 SBE, 
Inc. 
 
4000 Executive Parkway, Suite 200 
 
San Ramon, CA 94583 
SBE’s Technical Support Department can be reached at 800-444-0990.  
 
2.6 Operating Environment 
The HW400c/2 is designed to function within the environment shown in Table 1. 
 
Table 1.  HW400c/2 Operating Environment 
 
Storage temperature  -40 to +85 C (-40 to +185 
°F) 
Operating temperature:  0 to 55 
°C (32 to 131 °F) ambient temperature with a minimum 
of 200 LFM airflow (basic configuration) 
Operating humidity:  10% to 90% non-condensing 
Storage humidity:  5% to 95% non-condensing 
Power requirements:  36.5 Watts max. (estimated, basic configuration) 
Voltages:  5V +5%/-3%, 3.3V +5%/-3%, 12V 
±5% (all required) 
 
 
 
 
Bring the HW400c/2 board to operating temperature in a non-condensing 
environment. The rate of change in board temperature should not exceed  
°C (35.6 °F) per minute. 