SBE HW400c/2 User Manual

Page of 104
 
HighWire HW400c/2 User Reference Guide Rev 1.0 
 
2.10.5 Switches 
The HW400c/2 contains single switch that is necessary for normal operation. The 
switch is an integral part of the lower ejector handle inside the front panel, and is 
used along with the blue LED (see Figure 3) and the Linear Systems LTC1644, for 
hot swap. The switch is connected to the PC board at J10 near the lower ejector 
handle.  
 
For debugging purposes an optional reset/NMI toggle switch and cable is available 
(see Section 3.1.3). Please contact SBE Technical Support for details. 
 
2.10.6 Product Configurations 
The HW400c/2 can be manufactured with several configuration options.  Specific 
options include processor type and speed, memory amount, and CompactPCI 
connector configuration. See Table 6, Table 16, and Section 3.2.3 for related 
information.   
 
 
 
Table 5. HW400c/2 Order time options 
 
 
Standard Configuration 
Options 
CPU Speed 
1.0 GHz 
1.4 Ghz, 1.7Ghz  
(see Section 3.1) 
DDR RAM 
256MB 
512MB, 1GB  
(see Section 3.2.2) 
H.110 CT bus 
Installed 
CompactPCI bus 
Installed 
 
 
 
Options or modifications are available upon request. Please call SBE Sales for option 
availability, and/or modification requests. 
 
 
 
Build options have significant impact on power consumption. 
 
 
 
October 10, 2006 
Copyright 2006, SBE, Inc. 
Page 
12