Emerson ATCA-9305 User Manual

Page of 184
System Management:
 Vendor Commands
7-25
Get Status
The IPMC firmware notifies the payload about changes of all status bits except for bits 0-2 
by sending an unprintable character (ASCII 07, BELL) over the Payload Interface. The pay-
load is expected to use the Get Status command to identify pending events and other SIPL 
commands to provide a response (if necessary). The event notification character is sent in a 
synchronous manner, and does not appear in the contents of SIPL messages sent to the pay-
load.
Table 7-17:
Get Status Command
Set Local FRU LED State 
OEM
2E, 2F
18
Get Local FRU LED State 
OEM
2E, 2F
19
Update Discrete Sensor 
OEM
2E, 2F
1A
Update Threshold Sensor 
OEM
2E, 2F
1B
Reserved for Message Listeners
OEM
30, 31
10
Add Message Listener
OEM
30, 31
11
Remove Message Listener
OEM
30, 31
12
Get Message Listener List
OEM
30, 31
13
Update Firmware Progress Sensor
OEM
30, 31
F0
Type:
Byte:
Data Field: 
Request Data
1:3
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
Command:
  (continued)
netFn:
LUN:
Cmd: