Emerson MVME147 User Manual

Page of 170
Verify CRC Packet
7-51
7
Verify CRC Packet
The verify Cyclic Redundancy Character (CRC) command ($13) instructs the 
controller to read the specified number of blocks and check the CRC of each 
block.  The verify begins at the current tape position and the tape is left 
positioned at the end of the last block verified.  No data is transferred to the 
MVME147 during this operation.  
N
ote
 
The controller must be in general or read mode.  
The table below shows the verify CRC packet.  
Even Byte \
Odd Byte \
FC
B8
74
30
+$00
Controller LUN
Device LUN
+$02
Status Byte 0
Status Byte 1 (Note 1)
+$04
Number of Blocks (MSW)
+$06
Number of Blocks (LSW)
+$08
0
0
0
0
+$0A
0
0
0
0
+$0C
0
0
0
0
+$0E
0
0
0
0
+$10
0
0
0
0
+$12
0
0
0
0
+$14
0
0
Function Code (40)
+$16
Interrupt Level
Vector Number
+$18
Status Byte 2
Status Byte 3 (Note 1)
$00
00000xxx
Controller logical unit 
number
$01
00000xxx
Device logical unit 
number