Emerson PMC-CGM User Manual
PMC-CGM Installation and Use (6806800D53C)
MIB Description
cgmControl
48
.1.1.1.1.3
cgmInputFrequency
Configures the input frequency:
0: 8 KHz
1: 1544 KHz / 2048 KHz, depending on E1/T1
operation.
operation.
3: 19.44 MHz
r/w
.1.1.1.1.4
cgmT0InputPriority
This setting is applied to the protection partner
as well.
as well.
A priority value from 2 to 15 used by the T0 PLL
to select an input. A lower numerical value
means a higher priority. A value of 0 disables
the input, that means it will not be selected as
reference clock. A value of 1 cannot be set as
it is used for the master/slave synchronization
clock.
to select an input. A lower numerical value
means a higher priority. A value of 0 disables
the input, that means it will not be selected as
reference clock. A value of 1 cannot be set as
it is used for the master/slave synchronization
clock.
Default value is 0.
r/w
.1.1.1.1.5
cgmT4InputPriority
Priority of frequency monitor (T4 Path). Lower
numerical values represent a higher priority
than greater values.
numerical values represent a higher priority
than greater values.
A value of 0 means that the input will never be
selected as active input.
selected as active input.
Default value is 0.
r/w
.1.1.1.1.6
cgmInputState
Indicates whether the input receives a valid
clock or not.
clock or not.
r/w
.1.1.1.1.7
cgmInputActivityMonitorEna
Controls whether the activity monitor for this
input is enabled.
input is enabled.
r/w
.1.1.1.1.8
cgmInputActivityMonitorState
Reports the state of the activity monitor for this
input.
input.
r
Table 5-3 Input Assignments
Instance
cgmInputNumber
cgmInputName
Default
cgmInputFrequency
cgmInputFrequency
2
3
BITS1
freqE1T1 (1)
3
4
BITS2
freqE1T1 (1)
6
7
REFA
freq8K (0)
10
11
MS_SYNC
freq8K (0)
11
12
REFB
freq8K (0)
Table 5-2 cgmInputTable (continued)
OID
MIB Object
Description
Access