UPS Operations with SmartSlot card.
The table documents how UPS devices operate with the card.
Types of Interface
UPS:
UPS operational issue
Smart Serial: DB-9F smart signaling interface
Simple: Simple Signal interface via DB-9F
USB:
USB-B port on the card.
I
NTER
-
FACE
C
OMMAND
OR FUNCTION
H
ISTORIC
O
PERATION
O
PERATION
W
ITH
L
EGACY
C
OMMUNICATIONS
S
MART
S
LOT
C
ARD
INSTALLED
1 Simple Remote On
Not always supported. Some UPS devices
allowed starting with the Remote On signal
when AC utility power was off.
allowed starting with the Remote On signal
when AC utility power was off.
Remote On is enabled when AC utility power is on OR
when AC power has been off for less than 10 minutes.
when AC power has been off for less than 10 minutes.
2 UPS
On button operation UPS turned on immediately.
UPS turns on after the configured Turn on Delay. The
default setting is "0" (zero) - immediately turn on.
default setting is "0" (zero) - immediately turn on.
3 UPS
Switched Outlets
Were not supported.
Where relevant, switched outlet operation is disabled: all
the UPS outlets function simultaneously. (The Main
Outlet Group might turn on slightly before, and turn off
slightly after, the other outlets). Switched outlet-related
LCD menu screens are not accessible.
the UPS outlets function simultaneously. (The Main
Outlet Group might turn on slightly before, and turn off
slightly after, the other outlets). Switched outlet-related
LCD menu screens are not accessible.
4 UPS
RJ-45 comms port
Was not supported.
Disabled.
5 UPS
USB comms port
Differed, depending on setup.
Disabled.
6 UPS
Self-test Operation Could always be initiated.
1. A self-test is enabled on extended-run UPS devices
with more than 8 hours runtime. 2. A UPS might prevent
a self-test if the battery charge is < 70%.
with more than 8 hours runtime. 2. A UPS might prevent
a self-test if the battery charge is < 70%.
7 UPS
Runtime Calibration A runtime calibration could be initiated,
regardless of load and battery charge.
Two conditions must be met: 1. The battery charge must
be 100%. 2. The load must be => 10% of the UPS rating.
be 100%. 2. The load must be => 10% of the UPS rating.
8 Smart
Serial
Test lights and
beeper
beeper
The UPS beeped for 1.5 seconds
Beep operation is determined by the UPS; some newer
UPS devices have a 5 second beep.
UPS devices have a 5 second beep.
9 Smart
Serial
Simulate Power
Failure
Failure
The UPS operated momentarily on battery. The UPS does not go to battery operation, but
temporarily remembers this command (in order to enable
the Shutdown on Battery command).
the Shutdown on Battery command).
10 Smart
Serial
Establishment of
Communications
Communications
Serial communications had to be re-
established each time the UPS turns on.
established each time the UPS turns on.
No change.
11 Smart
Serial
Minimum battery
capacity to restart
capacity to restart
After a complete discharge of batteries in an
outage, the UPS restarted when the battery
charge reached this value.
outage, the UPS restarted when the battery
charge reached this value.
The UPS reads the value as a %, and restarts as follows:
0%—an immediate restart; 15%—with runtime of 90
secs.; 30%—with runtime of 180 secs.; up to a
maximum 90%—restarts with runtime of 240 secs.
0%—an immediate restart; 15%—with runtime of 90
secs.; 30%—with runtime of 180 secs.; up to a
maximum 90%—restarts with runtime of 240 secs.
12 Smart
Serial
Battery Replacement
Date
Date
Any 8 characters were supported.
The date format must be mm-dd-yy, with any separating
character (“-” here) supported. Dates prior to the UPS
manufacture date are not accepted.
character (“-” here) supported. Dates prior to the UPS
manufacture date are not accepted.
13 Smart
Serial
Alarm delay after
line fail
line fail
On some UPS devices you could set the
beeper to sound after being on battery for 30
secs, or at low battery. All UPS devices
could mute and disable the beeper.
beeper to sound after being on battery for 30
secs, or at low battery. All UPS devices
could mute and disable the beeper.
UPS devices can enable, disable or mute the alarm. If
beeping at low battery or on battery is selected, the alarm
is disabled, but the setting is displayed on the LCD
screen.
beeping at low battery or on battery is selected, the alarm
is disabled, but the setting is displayed on the LCD
screen.
14 Smart
Serial/
USB
USB
UPS Model
Returned the device name, e.g. Smart-UPS
750VA
750VA
Returns the closest equivalent historical name, which
might be different from the name displayed on the LCD
screen.
might be different from the name displayed on the LCD
screen.
15 Smart
Serial
Nominal Battery
Voltage
Voltage
Reported the nominal battery voltage of the
UPS.
UPS.
The nominal battery voltage is not known so the card
“estimates” it and returns 024, 048, or 192; if an estimate
is impossible, the card reports 024.
“estimates” it and returns 024, 048, or 192; if an estimate
is impossible, the card reports 024.
16 Smart
Serial
Upper Transfer
Voltage
Voltage
For SURTD UPS devices, the card displays the
corresponding bypass limit; but the allowable range of
values is determined by the voltage setting of the UPS.
corresponding bypass limit; but the allowable range of
values is determined by the voltage setting of the UPS.
17 Smart
Serial
Lower Transfer
Voltage
Voltage
18 USB
DelayBeforeReboot The Turn Off Delay setting was applied
before turning the UPS off, the UPS
remained off for the time specified, and was
then turned back on immediately.
remained off for the time specified, and was
then turned back on immediately.
The Turn Off Delay setting is applied before the UPS is
turned off, the UPS remains off for the time specified,
and the Turn On Delay is applied before the UPS is
turned back on.
turned off, the UPS remains off for the time specified,
and the Turn On Delay is applied before the UPS is
turned back on.
19 USB
USB communication Not present on SURTD UPS devices.
Not functional when installed in a SURTD UPS device.