Test-Um NT955 User Manual

Page of 97
73
Test-Um NT955 Series
Performing a Bit Error Rate Test  
A Bit Error Rate Test (BERT) sends data packets from the main unit to 
the remote, measures speed and errors and correlates this to a PASS or 
FAIL result. This test can only be run from end to end on a single cable, it 
cannot be run through an Ethernet hub or switch.
1.  From the Data Manual Tests screen, select the BERT Test 
button. (Figure 5.9)
2.  Using the drop down dialog box, select an Ethernet speed of 1 
gigabit or 100 Megabits. Press Accept
3.  Select the number of bits to transfer from the drop down dialog 
box. Press Accept.
4.  Press the Test button to begin the run.  The % Complete will 
advance as the test proceeds and any errors will be reported as 
the % Completed is updated.  A Pass or Fail will be displayed at 
the end of the test based on the industry standard of not more 
than one error in 10 Gigabits transferred.  
Ethernet Speed:
Bits to Transfer:
BERT Test
Untitled1.job
1 Gbit/s
10 Gbits
% Completed:
Test Rate:
Error:
Test-Um Inc.
validator
100%
2005 Aug 25
  10:53:01
Figure 5.9 Bit Error Rate Test
 
Validator
TM
 Running Manual Tests