SATO 9001147B User Manual

Page of 12
SATO RFID User Guide
PN 9001147B
Page 4
RFID SPECIFIC MENU ITEMS
The LCD menu items specific to RFID are located in the Service Mode menu area. To reach the
Service Mode menu area, power the printer on while pressing and holding the LINE and FEED
keys. Release the keys upon hearing the printer beep. Press the LINE key twice, and then the
FEED key to enter the Service Mode menu items.
The following LCD menus are specific to RFID operation:
RFID MENUS
DISPLAY
DESCRIPTION
Sets the number of times the printer will attempt to re-encode
and re-print data following a Tag Error. The printer will enter the
error mode when the entered number of retries has been met.
The default is 00. The range is 00 to 99.
Sets the printer response after the “REPRINT CONT” has
been reached. When “STOP” is selected, the printer will enter
an error state that can be cleared by pressing the LINE key.
Selecting “AUTO” will allow the error to be cleared by the next
PRINT START signal from the applicator.
Sets the RFID Tag Error output for either a level signal or a
pulse signal. The default is Level.
When “PULSE” is selected in the previous menu, the length of
the pulse can be set through this menu item. The default is
100ms. The range is 100 to 500 ms increments.
Selecting “YES” prints the message “RFID TAG ERROR” and
a diagonal slash through the label. For the slash to print to the
size of the label, the Media Size command (<ESC>A1) must
be included in the data stream. Selecting “NO” prints only the
message “RFID TAG ERROR” at the top of the label. The
default is YES.