Multi-Tech Systems E1 User Manual

Page of 395
Operation and Maintenance 
 
MultiVOIP User Guide 
282 
 
T1 Statistics: Field Definitions (cont’d) 
Field 
Name 
Values Description 
Yellow 
Alarm 
Tally since last 
reset. 
The alarm signal sent by a remote T1/E1 
device to indicate that it sees no receive 
signal or cannot synchronize on the 
receive signal. 
Frame 
Search 
Restart Flag 
 
[To be supplied.]
 
Loss of 
MultiFrame 
Alignment 
Tally since last 
reset. 
In D4 or ESF mode, displayed value will 
increment if multiframe alignment has 
been lost or if loss of frame alignment has 
been detected. 
Transmit 
Slip 
Tally since last 
reset. 
Slip in transmitted data stream.  Slips 
indicate a clocking mismatch (or lack of 
synchronization) between T1/E1 devices.  
When slips occur, data may be lost or 
repeated. 
Pulse 
Density 
Violation 
 
The pulse density of the received data 
stream is below the requirement defined 
by ANSI T1.403 or more than 15 
consecutive zeros are detected. 
Line 
Loopback 
Activation 
Signal 
 
The line loopback activation signal 
has been detected in the received bit 
stream. 
Transmit 
Line Open 
 
At least 32 consecutive zeros were 
transmitted. 
 
Transmit 
Data 
Underrun 
 
For use by MTS Technical Support 
Personnel. 
 
Transmit 
Slip 
Negative 
 
The frequency of the transmit clock is 
greater than the frequency of the 
transmit system interface working 
clock. A frame is skipped.