Campbell Manufacturing RF415 User Manual

Page of 90
B-1
Appendix B.  Setup Menu
Here is the structure of the RF400 series’ built-in Setup Menu system which can be
accessed by configuring a terminal emulator program such as Procomm
TM
 or
HyperTerminal
TM
 to 9600 baud (8-N-1) and pressing the “Program” button on the
RF400 with RF400’s RS-232 port cabled to appropriate COM port of PC.  Also
displayed is a number representing the radio’s software and RF module versions.
For example:  6.425.
MAIN MENU
SW Version 6.425
1)  Standard Setup
a)  Active Interface
i)  Auto Sense
ii)  RS-232
iii)  Datalogger Modem Enable
iv)  Datalogger SDC
(not for Table Based Loggers)
v)  Datalogger CSDC
(only for Table Based Loggers)
vi)  COM2xx to RF400
b)  Net Address (0 – 63)
c)  Radio Address (0 – 1023)
d)  Hopping Sequence ( 0 - 6)
e)  Standby Mode  (select one of the following)
i)  <24 mA  Always On
ii)  < 4 mA  1/2 sec Cycle
iii)  < 2 mA  1 sec Cycle
iv)  < .4 mA  8 sec Cycle
2)  Advanced Setup
a)  Radio Parameters
i)  Radio Address Parameters
(1)  Net Address
(0 – 63)
(2)  Radio Address
(0 – 1023)
(3)  Net Address Mask
(0 – 3fh)
(4)  Radio Address Mask
(0 – 3ffh)
(5)  Hop Table
(0 – 6)