Symptom-to-FRU Index
 Power-Related Symptoms
Symptom / Error
FRU / Action in Sequence
Power shuts down during
operation.
1. Go to “Power
Systems Checkout”
on page 35.
  2. Battery pack
3. Remove the battery
pack and let it cool for
2 hours.
  4. System board
5. Check the power
outlet.
The system does not power
off.
(See “Reset Switch” on
page  23.)
1. Press the power
shutdown switch.
  2. System board
 Other Symptoms
  Note 
If you cannot find a symptom or an error in this list
and the problem remains, see “Undetermined
Problems” 
Symptom / Error
FRU / Action in Sequence
Errors occur only when the
port replicator is used.
See “Port Replicator
Checkout” on page 35.
PC Card slot pin is
damaged.
1. PC Card slots
assembly
 Intermittent Problems
Intermittent system hang problems can be caused by a
variety of reasons that have nothing to do with a hardware
defect, such as: cosmic radiation, electrostatic discharge,
or software errors. FRU replacement should be
considered only when a recurring problem exists.
When analyzing an intermittent problem, do the following:
1. Run the advanced diagnostic test for the system
board in loop mode at least 10 times.
2. If no error is detected, do not replace any FRUs.
3. If any error is detected, replace the FRU shown by
the FRU code. Rerun the test to verify that no more
errors exist.
 Undetermined Problems
You are here because the diagnostic tests did not identify
which adapter or device failed, installed devices are
incorrect, a short circuit is suspected, or the system is
inoperative. Follow these procedures to isolate the failing
FRU (do not isolate nondefective FRUs).
64