4.  Extension starts. If UDV needs initialization, it will display an “I” in 
“Status 3”
 and complete percentage of initialization in “R%”
 
 
Figure 4.3.1 
(Figure 4.3.1: Extend UDV-R0 from 80GB to 90GB.) 
 
 
 
 
 
Tips
 
The size of UDV extension must be larger than original. 
 
 
 
 
 
 
Caution
 
UDV Extension cannot be executed during rebuild or migration.
 
 
4.4  Disk roaming 
 
Physical disks can be re-sequenced in the same system or move whole physical 
disks from system-1 to system-2. This is called disk roaming. Disk roaming has 
some constraints as described in the following: 
 
1.  Check the firmware of two systems first. It is better that both have 
same firmware version or newer. 
2.  Whole physical disks of related VG should be moved from system-1 to 
system-2 together. The configuration of both VG and UDV will be kept 
but LUN configuration will be cleared to avoid conflict with system-2.  
- 62 -