Nokia 12 GSM MODULE REMOTE I/O User Manual

Page of 53
 
 
Note: If an alias is defined, the default command will be disabled. There can be 
only one effective command or alias for each function at a time. An alias must not 
be equal to a default command. 
Empty aliases cannot be used. If an empty alias is set, the default command will 
remain effective. 
 
Note: The alias string must be unique and the maximum length is 24 characters. 
Neither commands nor aliases are case sensitive. However, the message identifier 
and password are. 
 
Table 5. List of response messages 
Response Message 
Description 
OUTPUT x: ON 
Alias for output x on state, x = pin number 1-9 
OUTPUT x: OFF 
Alias for output x off state, x = pin number 1-9 
INPUT x: *
 
Alias for input x voltage *, x = pin number 1-3
 
INPUT x: ON 
Alias for input x on state, x = pin number 4-11 
INPUT x: OFF 
Alias for input x off state, x = pin number 4-11 
* The value of the sampled voltage will be added to the end of the response. The value of the sampled voltage is 
between 0 – 2800 mV, for example:  
INPUT 1: 10mV
 
9.3 
DETAILED COMMAND INFORMATION AND RESPONSES  
All example commands in this chapter use the “term123” identifier string, and 
the password property is set off in all of the subsequent chapters. 
 
Note: If a command or the alias defined for it is not identified, but the identifier and 
the optional password are correct, the Nokia 12 GSM Module will send an error 
message as a response to the command originator, for example: 
Control message: 
term123 passWORD ResetAll
   
Response:  
ERROR (Unknown Command)
 
9.3.1 Changing 
the 
Password 
Use the Change_Pword command to control the password. Note that all 
example commands in this chapter use the “term123” identifier string (see 
Table 6). 
 
 
 
 
29/49