Nokia 12 GSM MODULE REMOTE I/O User Manual

Page of 53
 
INPUT 11: Y 
The Y varies according to the input pin state and it can 
be: 
xxxx mV
 if the input is in analog mode (pins 1-3) 
(xxxx=value between 0-2800) 
ON or OFF if the input is in digital mode (pins 4-11) 
Input_Get_Change X 
 
 
term123 Input Get Change 
Response:  
INPUT_GET_CHANGE Z:  
INPUT X: Y 
The X refers to input pin number, 
X=1,2,3,4,5,6,7,8,9,10,11. 
The Y refers to success state and it can be: 
OK
 or 
CHECK CONFIG
 
Event data, when input state has changed, contains the 
following information: 
INPUT X: Y 
The X refers to input pin number, 
X=1,2,3,4,5,6,7,8,9,10,11. 
The Y varies according to the input pin state and it can 
be: 
ON
 or 
OFF
 if the input is digital (4-11) 
xxxx
 
mV
 if the input is analog (1-3) (xxxx=value 
between 0-2800) 
The command 
subscribes an alarm 
for input pin X and the 
response returns the 
state of it according to 
input pin configuration 
Input_Change_Cancel  
 
term123 
Input_Change_Cancel X 
OK Response:  
INPUT_CHANGE_CANCEL X: 
OK 
The X refers to input pin number, 
X=1,2,3,4,5,6,7,8,9,10,11,all.  
The command 
cancels an alarm 
subscription for input 
pin X  
9.3.4 Reading 
Outputs 
Use the Output_Get X commands for reading digital output states. Note that all 
example control messages in this chapter use the “term123” identifier string and 
the password property is set off (see Table 9). 
 
 
34/49