Automatic Clock Adjustment Error Processing
Section 12-4
The error log can be read by sending FINS commands to the EtherNet/IP Unit
or built-in EtherNet/IP port or by using the mail receive function and specifying
the ErrorLogRead command.
Error 
code
Meaning
Detailed error code
Correction
EEPROM
1st byte
2nd byte
03C1
Server set-
ting error
00H: DNS
03H: 
SNTP
04H: FTP
06H: 
BOOTP
07H: 
SNMP
08H: 
SNMP 
Trap
09H: 
FINS/
UDP
0AH: 
FINS/
TCP
01: IP address
02: Host name
03: Port number
04: Other 
parameters
Set the server 
settings correctly 
based on the 
information in the 
detailed error 
code.
---
03C4
Server 
connection 
error
00H: DNS
03H: 
SNTP
04H: FTP
06H: 
BOOTP
07H: 
SNMP
08H: 
SNMP 
Trap
01: Specified 
host does not 
exist
02: No service 
at specified host
03: Timeout
04: Closed uni-
laterally by host
05: Cannot con-
nect because 
account infor-
mation does not 
match
06: Host name 
resolution error
07: Transmis-
sion error
08: Reception 
error
09: Other error
0AH: Error in 
obtained IP 
address
Take either of the 
following mea-
sures.
• Correct the set-
tings for each 
server.
• Inspect the com-
munications 
path (EtherNet/
IP Unit or built-in 
EtherNet/IP 
port), cable con-
nections, hub, 
router, server), 
and correct the 
situation that is 
causing the 
error.
---
03C6
Clock data 
write error
0001: Clock data could not 
be refreshed because of a 
CPU Unit error.
Clear the CPU 
Unit error.
---
0002: Clock data could not 
be refreshed because the 
CPU Unit could not write 
clock data in that operation 
mode.
The automatic 
clock adjustment 
function is not 
supported by cer-
tain CPU Units 
(models, lot num-
bers) if they are in 
RUN or MONI-
TOR mode.
(See note.)
---