Telect MIX 56 User Manual

Page of 124
MIX 56 User Manual
4  Software Operation
122188-10 A0
Telect, Inc.
4-41
Step
Action
1.
From the Directory screen, press 16 to select Current Alarms, then 
Enter.
The Current Alarms screen appears:  
2.
Tab to “Card Select” and press the spacebar to toggle between “Ac-
tive” and “Standby”. Press Enter.
3.
To view the next 14 entries, tab to [Next] and press Enter.
4.
To view the previous 14 entries, tab to [Previous] and press Enter.
5.
To engage or disengage the ACO, tab to the button below the Time 
Remaining field and press Enter. If the ACO is engaged, the button 
that appears is [Disengage ACO]. If the ACO is disengaged, the 
button that appears is [Engage ACO].
To View the Alarm Log
You can view a history of alarms in the Alarm Log, a screen that displays 
the last 99 alarm entries. An entry is made in the Alarm Log when an alarm 
is triggered, and again when it is cleared.
Each page in the Alarm Log contains up to11 entries that show the date and 
time each alarm started or ended, the type of alarm, and a detailed explana-
tion of the alarm. You can move forward or backward through the pages, 
and when finished viewing alarms, you can clear the entire log.
MIX 56 by Telect                     system 2                 Directory (Ctrl+D)
                                                                        Help (?)
                             Current Alarms - Active
                             -----------------------    Alarm Cutoff: Disengaged
Card Select: Active                                   Time Remaining: 00:00
                                                                [Engage ACO]
Alarm Details                                              Start Date / Time
----- ---------------------------------------------------- ------------------
Crt   multiple low speed failures                          22/Oct/03 07:37:35
Mjr   LS-02(Low Speed 02),LOS                              22/Oct/03 07:37:35
Mjr   LS-03(Low Speed 03),LOS                              22/Oct/03 07:15:02
Mjr   LS-01(Low Speed 01),Rx AIS                           22/Oct/03 07:14:49
Mjr   15 min. ES LS threshold crossed                      22/Oct/03 07:16:04
Mjr   15 min. SES LS threshold crossed                     22/Oct/03 07:14:56
Mjr   24 hr. ES LS threshold crossed                       22/Oct/03 07:29:59
Mjr   24 hr. SES LS threshold crossed                      22/Oct/03 07:29:59
Mnr   backup power B failed                                22/Oct/03 07:13:00
                                    Page: 1                   [Next]  [Previous]