Emulex 375 User Manual

Page of 77
E
MULEX
 M
ODEL
 375 SAN S
TORAGE
 S
WITCH
U
SER
S
 G
UIDE
A
PPENDIX
 C: E
VENT
 M
ESSAGES
E
MULEX
 C
ORPORATION
68
P
ART
 N
UMBER
 00041392-002 R
EV
. B
A
PPENDIX
 C
Event Messages
The event messages for the switch are listed below. For explanations, contact a customer service 
representative. The message’s applicable severity level as defined below is also provided.
These severity levels can be used to designate which events trigger trap messages. Use the Command 
Line Interface (CLI) to designate the minimum severity level of events to be logged in the Event Log and 
at which severity level to illuminate the switch’s Fault LED. 
Severity 
Level
Severity
Description
1
EMERG
Immediate action required; system failing
2
ALERT
Unrecoverable condition reported; major event in progress
3
CRIT
Event failed with possible loss of integrity
4
ERR
Condition failed; action required
5
WRN
Failed event occurred; no action required
6
NOTIFY
Configuration error or abnormal event occurred; no action required
7
INFO
Event occurred; no action required
Event
Event Message
Severity
1
Message log cleared
INFO
5
Power Supply # Failed
ALERT
6
Power Supply # Online
NOTIFY
7
Power Supply # Removed
ALERT 
8
Power Supply # Inserted
NOTIFY
9
Fan has stopped
EMERG
10
Fan has returned
ALERT
19
Temperatures over limit
ALERT
20
Temperature OK
INFO
50
SPF Overvoltage
EMERG
54
SOC has detected a CRC error in the EEPROM
NOTIFY
70
PORT # bypassed
NOTIFY
71
PORT # inserted
NOTIFY
72
Transceiver detected at port #
NOTIFY
73
Transceiver removed at port #
NOTIFY
74
SEOC occurred on PORT #
NOTIFY
75
Port exceeded OS threshold
NOTIFY
76
Port exceeded CRC threshold
NOTIFY
77
Loop UP on Port #
NOTIFY
78
Loop DOWN on Port #
NOTIFY
79
PORT received a LIP(F8)
WRN
80
PORT CRC Error detected in frame
WRN
81
PORT did not receive LIPF7) within timeout
WRN