Enterasys Networks 2E43-27 User Manual

Page of 77
FddiMAC Device Configuration View
Configuration Views
Fast Ethernet SmartSwitch Module
3-6
Management Module Guide
FddiMAC Device Configuration View
The FddiMAC Device Configuration view provides configuration and 
operating status information.
To access this view, do the following:
1.
Highlight the FddiMAC icon in the Application view (Icon mode) or the 
FddiMAC text label (List mode).
2.
From the View menu, select Icon Subviews -> Configuration or click 
the applicable mouse button (middle or right) and select Configuration.
Station Configuration 
This section of the FddiMAC Device Configuration view provides the following 
configuration information on the FDDI station.
Ring State
The current state of the FDDI Ring. Table 3-2 lists the possible states and 
their descriptions.
Table 3-2.
FDDI Ring States
Ring 
States
Description
Isolated
The concentrator is not attached to the ring.
Non-Op
The concentrator is attempting to enter the ring.
Ring-Op
The ring is operational.
Detect
The claim/beacon process of the FDDI ring protocol has exceeded 
one second. This indicates a potential problem.
Non-Op-Dup
The ring failed to complete the claim/beacon process because a 
duplicate FDDI address has been detected.
Ring-Op-Dup
The ring is operational, but a duplicate FDDI address has been 
detected.
Directed
The claim/beacon process did not complete within nine seconds. 
The concentrator is now sending directed beacons to indicate a 
problem.
Trace
A problem has been detected with the station or its upstream 
neighbor. A trace is being sent to notify the upstream neighbor of 
the problem. The concentrator and all stations between the 
concentrator and its upstream neighbor can perform self-tests.