RAD Data comm RIC-155 User Manual

Page of 90
RIC-155 Installation and Operation Manual 
Chapter 4  Configuration 
 
Displaying the RIC-155 Status 
4-17 
Table 4-1.  DATA/MNG Port Status Parameters 
Parameters Values 
Link Status 
•  Link Up – DATA/MNG link is up 
•  Link Down – DATA/MNG link is down 
Autonegotiation 
•  Disabled – Autonegotiation is disabled 
•  Not Finished – Autonegotiation is being currently performed 
•  Complete – Autonegotiation process is completed 
Duplex State 
•  Full Duplex – Full duplex operation 
•  Half Duplex – Half duplex operation 
Speed State 
•  10 Mbps – 10 Mbps LAN speed 
•  100 Mbps – 100 Mbps LAN speed 
Partner Pause 
•  Unknown – Autonegotiation process is not completed 
•  MAC Pause not Implemented – MAC pause is not implemented in the link partner 
•  MAC Pause Implemented – MAC pause is implemented in the link partner 
Line Indication 
•  Normal – Primary/management link operates properly 
•  Major – A major alarm is detected on the DATA/MNG link 
•  Minor – A minor alarm is detected on the DATA/MNG link 
Displaying the STM-1/OC-3c Port Status 
Status of the STM-1/OC-3c port can be displayed via the Uplink Status menu.
 
 lists parameters provided in Uplink Port Status screen. 
 
To display the STM-1/OC-3c port status: 
•  Follow the path: Monitoring > Physical Port Monitoring > Physical Port Status 
Uplink Status
The Uplink Status screen appears (see 
). 
RIC-155 
Uplink Port Status 
    Uplink Connector Type 
>(Two BNC) 
    Section 
 
>(Normal) 
    Line  >(Normal) 
    Path  >(Normal) 
    Line Indication 
  >(Normal) 
 
ESC-prev.menu; !-main menu; &-exit 
Figure 4-20.  Uplink Status Screen