Promise Technology TX4 User Manual

Page of 54
UltraTrak100 TX4 and UltraTrak100 TX8  User Manual 
6
 
(the one which is attached to the SCSI adapter) to the top connector, and 
place an LVD SCSI active terminator on the other connector. An LVD SCSI 
active terminator is included with UltraTrak100 disk array unit. 
• 
If the array is to be placed in the middle of a daisy-chained configuration, 
connect the incoming cable (the one which is attached to the SCSI adapter) 
to the top connector and connect the outgoing cable (the one which 
continues on to other devices) to the other connector. In this case, no 
terminator is required at the array, but the last device in the daisy chain must 
be terminated. 
Correct SCSI termination procedures require that the first and last devices on the 
SCSI bus be terminated. If the first or last device is not terminated, or if devices 
other than the first and last are terminated, erratic SCSI bus performance will 
occur. Typically, the system or host adapter is the first device and is already 
terminated. When installing the UltraTrak100 disk array on a SCSI bus with other 
devices, make sure the above rules are observed with all devices on the SCSI 
bus. Consult your system and/or host adapter manual for additional information on 
correct termination procedure.  
 
Caution 
 
 
Improper system operation will occur if the SCSI termination is incorrect. 
Active termination and SCSI-3 compliant cables must be used. A SCSI-3 
compliant cable is included with the UltraTrak100. 
D
AISY 
C
HAINING 
M
ULTIPLE 
A
RRAYS
 
Use a standard 68-pin SCSI-3 cable assembly to attach the array to the SCSI 
chain. Attach each cable to the individual units to be connected on the SCSI bus. 
Ensure that each device has a unique SCSI ID and that only the first and last 
devices are terminated. 
Computer or
Workstation
UltraTrak100 TX4
Terminator
UltraTrak100 TX4
UltraTrak100 TX4
 
Figure 3.  Daisy Chaining Several UltraTrak100s Together 
D
AISY 
C
HAINING WITH 
O
THER 
SCSI D
EVICES
 
This procedure is essentially the same as the procedure outlined above for 
multiple arrays. Refer to the manual associated with the other device or devices 
for additional information that may be pertinent to that unit. Ensure that each