2-30 
Server Cards
Model No.
Running Head
ACS-FRS Card Troubleshooting
FRS Card
5. Go to the Circuits Screen of the FRS card (which can be accessed by selecting Circ 
from the FRS Main Screen). Verify that the affected circuit STATUS is up (indicated 
by a “U”). If it is not up, this may indicate that an LMI is down in the far end of the 
circuit. Highlight the affected circuit and type P and the performance registers for the 
circuit will appear. Analyze the information provided to help determine the cause of the 
problem.
6. Loopbacks are available on the “C” ports only. If a “C” port with an LMI is looped back 
toward itself, the PORT TYPE must be nni for the loopback to function.
7. If the FRS card is determined to be faulty, replace it and return the faulty unit for repair 
to the location specified by your distributor.