12.8  Synchronous Communications on Ports E and F
Serial Port E and F are a dual-function serial ports that can be used in either asynchronous 
or HDLC mode. Four bytes of buffering are available for both receiver and transmitter to 
reduce interrupt overhead. An interrupt is generated whenever at least one byte is avail-
able in the receiver buffer and every time a byte is removed from the transmitter buffer.
Serial Port E is clocked by the output of Timer A2 and Serial Port F by A3. In asynchro-
nous mode this clock can be either sixteen (the default) or eight times the data rate. In 
HDLC mode this clock is sixteen times the data rate. Note that the fastest output from 
Timer A2 or A3 is the same frequency as the peripheral clock. Thus the maximum data 
rate is the peripheral clock frequency divided by eight in async mode and divided by six-
teen in HDLC mode.
The HDLC receiver employs a Digital Phase-Locked-Loop (DPLL) to generate a synchro-
nized receive clock for the incoming data stream. HDLC mode also allows for an external 
1x (same speed as the data rate) clock for both the receiver and the transmitter. HDLC 
receive and transmit clocks can be input or output, as appropriate, via the specified pins. 
When using an external clock, the maximum data rate is one-sixth of the peripheral clock 
rate.
In asynchronous mode the port can send and receive seven or eight bits and has the option 
of appending and recognizing an additional address bit. On transmit, the address bit is 
automatically appended to the data when this data is written to the address register or long 
stop register. Writing to the address register appends an “zero” address bit to the data, 
while writing to the long stop register appends an “one” address bit to the data. The 
address bit is followed by a normal stop bit. Normal data is written to the data register to 
be transmitted. On receive, a status bit distinguishes normal data from “address” data. This 
status bit is set to one if a “zero” address bit is received. In non-address bit applications, 
this indicates a framing error. This status bit can also indicate a received break, if the 
accompanying data is all zeros (this is the definition of break). Asynchronous mode oper-
ates full-duplex. Either the receive data available, transmit buffer empty or transmit idle 
conditions can be programmed to generate an interrupt.
The HDLC mode allows full-duplex synchronous communication. Either an internal or 
external clock may be selected for both the receiver and the transmitter. HDLC mode 
encapsulates data within opening and closing Flags, and sixteen bits of CRC precedes the 
closing Flag. All information between the opening and closing Flag is "zero-stuffed". That 
is, if five consecutive ones occur, independent of byte boundaries, a zero is automatically 
inserted by the transmitter and automatically deleted by the receiver. This allows a Flag 
byte (0x07E) to be unique within the serial bit stream. The standard CRC-CCITT polyno-
mial (x
16
 + x
12
 + x
5
 + 1) is implemented, with the generator and checker preset to all ones.
Both receive and transmit operation are essentially automatic. In the receiver, each byte is 
marked with status to indicate end-of-frame, short frame and CRC error. The receiver 
automatically synchronizes on Flag bytes and presets the CRC checker appropriately. If