Adder Technology AVX4016IP User Manual

Page of 115



Power control port
The.AdderView.CATx.IP.models.provide.
a.serial.port.for.connection.to.one.or.
more.optional.power.control.units..
This.allows.you.to.control.the.mains.
power.being.supplied.to.the.connected.
computer(s).so.that.an.authorised.user.
can,.if.necessary,.perform.a.complete.
remote.cold.reboot.on.a.failed.system.
The.control.connector.of.the.first.power.switch.is.attached,.via.serial.cable,.to.
the.rear.panel.of.the.AdderView.CATx.IP..Any.additional.power.switches.are.
then.attached.via.a.‘daisy-chain’.arrangement.to.the.first.power.switch..Each.
power.switch.box.is.then.given.a.unique.address.and.access.to.each.power.port.
(8.ports.on.each.power.switch.box).is.gained.using.a.combination.of.the.switch.
box.address.and.the.port.number..
To connect and address the switch boxes
Note: The AdderView CATx IP unit can be powered on during this procedure, 
however, the switch boxes should be switched off.
1. Mount.up.to.four.switch.boxes.in.positions.where.they.are.close.to.the.
computer.systems.that.they.will.control.and.not.too.distant.from.the.
AdderView.CATx.IP.unit.(preferably.within.2.5.metres).
2. Use.a.serial.cable.with.an.RJ9.and.a.9-pin.D-type.connector.(see.
.for.specification)..Attach.the.RJ9.plug.to.the.socket.marked.
IN
.on.the.first.
switch.box..Attach.the.other.end.to.the.socket.marked.
POWER CONTROL
.on.
the.AdderView.CATx.IP.
Power to computer
Box , port  - address: 
Box 
Box 
Box 
Box 
Power 
switch 
boxes
‘Daisy-chain’ 
control 
connections
The.power.ports.are.connected.to.the.power.inputs.of.each.computer.system.
and.the.power.switch.box(es).are.then.connected.to.a.mains.power.supply.
IMPORTANT: Power switching devices have a maximum current rating. It is 
essential to ensure that the total current drawn by the equipment connected 
to the power switching device does not exceed the current rating of the power 
switching device. You must also ensure that the current drawn from any mains 
socket does not exceed the current rating of the mains socket.
Setting.up,.configuring.and.using.power.switching.requires.three.main.steps:
•. Connect.and.address.the.switch.boxes.
•.
•. Operate.power.switching.
.or.
3. For.each.of.the.remaining.switch.boxes.(if.used),.use.a.serial.cable.with.RJ9.
connectors.at.both.ends.(see.
.for.specification)..Attach.one.
end.to.the.socket.marked.
OUT
.of.the.previous.box.and.the.other.end.to.the.
socket.marked.
IN
.of.the.next.box..
4. Set.the.addressing.switches.on.each.switch.
box.using.the.two.micro.switches.marked.
‘Slct’.on.the.front.panel..The.box.connected.
directly.to.the.AdderView.CATx.IP.is.Box.1.
and.so.on,.down.the.daisy-chain.line.to.Box.
4.at.the.end.
5. Attach.IEC.to.IEC.power.leads.between.
each.port.and.the.power.input.socket.of.
each.computer.system.that.requires.power.
switching..Carefully.note.to.which.power.
ports,.on.which.boxes,.each.computer.system.is.connected..If.computer.
systems.have.multiple.power.inputs,.then.each.input.must.be.connected.via.
separate.ports,.which.can.be.on.the.same,.or.different.boxes.
6. Connect.each.box.to.a.suitable.mains.power.input..
Now.proceed.to.the.configuration.stage.covered.in.the.
.section.within.the.Configuration.chapter.
 
Box
  Switch   Switch .
.
1
...
Off.
Off
.
2
.
On.
Off
.
3
.
Off.
On
.
4
.
On.
On
Off = switch upwards
On = switch downwards
Switch  is on the left side
AdderView CATx 
rear panel
Serial cable to first 