Adder Technology 1000 User Manual

Page of 54




Advanced Options
Advanced options are available only to the 
Admin user and consist of settings that are 
related to specialist areas such as power 
control and DDC.
ADDERVIEW CATx 1000
Advanced Options
DDC Options
Power Control
USB Country Code
Enter-Select
F1-More menus
Esc-Quit
Firmware Version 1.01b06
DDC Options
The options within this section are related to the Display Data Channel features 
supported by the AdderView CATx 1000. DDC is an industry standard format 
that allows computer systems to be informed of the capabilities of the video 
monitor connected to them.
DDC Source
Settings: AUTO, LOCAL, REMOTE, DEFAULT
Determines which user port monitor should be interrogated to discover its 
capabilities. AUTO begins with the local user port and if it fails, it then checks 
the remote port and if that also fails to produce a result, it uses a set of default 
values. The LOCAL and REMOTE settings force the unit to interrogate only 
the local and remote monitors respectively, and DEFAULT uses only the pre-
programmed settings.
DDC Refresh
Settings: AT START, DISABLED
AT START
 sets the AdderView CATx 1000 to read DDC information from the 
selected source at power up. When DISABLED, no new DDC data is sought and 
existing information is used. When viewing this menu, press F7 to discover DDC 
information from the chosen source immediately. 
To get here
1  From a local or remote keyboard, log on 
as a standard (limited options) or ‘admin’ 
user.
2  Press 
 
   (hotkeys can change).
3  Press   to select ‘More menus’.
4  Press   again to select ‘Advanced 
menus’.
5  Select ‘Setup Options’. 
Power Control
The options within this section are concerned 
with the operation of the 
POWER CONTROL
 
port when used to command optional system 
power control units.  
Baud Rate
Settings: 1200, 2400, 4800, 9600, 19200, 
38400, 57600, 115200 
Configures the communication speed of 
the 
POWER CONTROL
 port and must match 
the speed used by the connected power 
switch(es). Note: The PSU-8MASTER and PSU-
8SLAVE power switches supplied by Adder 
require a setting of 9600.
Format
Settings: NONE.8.1, ODD.8.1, EVEN.8.1, NONE.8.2, NONE.7.2, ODD.7.2, 
EVEN.7.2  
Configures the data format used by the serial port and must match the format 
used by the connected power switch(es). The NONE/ODD/EVEN portion relates 
to the parity checking; the 7/8 value is the size of the data byte and the 1/2 
value determines the stop bit(s) used after each data byte.
continued
ADDERVIEW CATx 1000
Power Control
Power Control
ENABLED
Baud Rate
Format
9600
NONE.8.1
Space-Toggle
-Up -Down
Esc-Quit