Lucent Technologies 9077 16S User Manual

Page of 150
Monitoring and Management Tools
Checking for hardware problems - grdiag
SP Switch Router Adapter Guide - 1.4 Update 2
 
 October 22, 1999   
3-23
When a media card does not boot after grdiag 
  
For grdiag to run, a card must be able to boot. If the grcard display does not include the slot in 
which the problem card resides, grdiag cannot operate on that card.
For example, grdiag cannot run diagnostics on the card in slot 1 of this router:
# grcard
 0      ATM_OC3_V2     running
 2      DEV1_V1        running
 3      HSSI_V1        running
“Switch receive error” can indicate hardware problem 
           
    
The 
Switch Receive Error
 means a media card has received a packet from the SP Switch 
Router backplane switch that contains errors. Here are examples of such packets sent by the 
card in slot 3 and received by the Ethernet card in slot 4:
Jul 20 02:25:04 grf400.site.com gritd: from 0:0x3:0:  
dst=0:0x40:16, src=0:0x3:0, type=GRID:  hwtype=ETHER_V1 cmd=MSGP 
'[RX] Switch Recieve Error.  Status: 0xb04\r\n'
          •
          •
          •
Jul 20 02:26:16 grf400.site.com gritd: from 0:0x3:0:  
dst=0:0x40:16, src=0:0x3:0, type=GRID:  hwtype=ETHER_V1 cmd=MSGP 
'[RX] Switch Recieve Error.  Status: 0xb04\r\n'
An occasional occurrence of this error in the 
gr.console
 log is part of normal operations and 
can safely be ignored.
However, if clusters of many such errors are reported, it is likely that there is a problem with 
the switch hardware in either the sending media card or the receiving media card. A card may 
need to be replaced. If you see the message repeated many times, please contact Customer 
Service.