Lucent Technologies 6000 User Manual

Page of 586
4-14
MAX 6000/3000 Network Configuration Guide
Configuring Individual WAN Connections
The Answer profile
Filter-related parameters
The Answer > Session Options subprofile contains the following filter-related parameters: 
Timing parameters
The Answer > Session Options timing parameters define how long a session can remain 
inactive before a call is cleared, whether the MAX unit uses the terminal-server idle timer, and 
how long a terminal server can remain idle before the session disconnects. Following are the 
parameters:
Miscellaneous Session Options parameters
The following Answer > Session Options parameters further define the session for an 
incoming call:
Parameter
Specifies
Data Filter
Number of a filter used to determine if packets should be forwarded or 
dropped. If both a call filter and data filter are applied to a connection, 
the MAX unit applies a call filter after applying a data filter. (Only 
those packets that the data filter forwards can reach the call filter.)
Call Filter
Number of a filter used to determine if a packet should cause the idle 
timer to be reset or a call to be placed. If both a call filter and data filter 
are applied to a connection, the unit applies a call filter after applying a 
data filter. (Only those packets that the data filter forwards can reach 
the call filter.)
Filter Persistence
Whether or not the filter or firewall assigned to an Answer profile 
should persist after the call has been disconnected.
Parameter
Specifies
Idle
Number of seconds the MAX unit waits before clearing a call when a 
session is inactive. 
TS Idle Mode
Whether or not the unit uses the terminal-server idle timer and, if so, 
whether both the user and host must be idle before the unit disconnects 
the session.
TS Idle
Number of seconds that a terminal-server connection must be idle 
before the unit disconnects the session.
Parameter
Specifies
Max Call Duration
Maximum duration in minutes of an established session for an 
incoming call. The connection is checked once per minute, so the 
actual time of the call is slightly longer (usually less than a minute 
longer) than the actual time you set.
Preempt
Number of idle seconds the MAX unit waits before using one of the 
channels of an idle link for a new call.