Lucent Technologies 6000 User Manual

Page of 586
Configuring Individual WAN Connections
The Connection profile
MAX 6000/3000 Network Configuration Guide
 4-35
Session Options 
The Connections > Session Options parameters define the characteristics of the session and 
filter specifications: 
Timing parameters
The Connections > Session Options timing parameters define how long a session is inactive 
before a call is cleared, whether the MAX unit uses the terminal-server idle timer, and how 
long a terminal server must be idle before the session disconnects:
Miscellaneous Session Options parameters
The following Connections > Session Options parameters further define the session for an 
incoming call:
Parameter
Specifies
Data Filter
Number of a filter used to determine if packets should be forwarded or 
dropped. If both a call filter and data filter are applied to a connection, 
the unit applies a call filter after applying a data filter. (Only those 
packets that the data filter forwards can reach the call filter.)
Call Filter
Number of a filter used to determine if a packet should cause the idle 
timer to be reset or a call to be placed. If both a call filter and data filter 
are applied to a connection, the unit applies a call filter after applying a 
data filter. (Only those packets that the data filter forwards can reach 
the call filter.)
Filter Persistence
Whether or not the filter or firewall assigned to a Connection profile 
should persist after the call has been disconnected.
Parameter
Specifies
Idle
Number of seconds the unit waits before clearing a call when a session 
is inactive. 
TS Idle Mode
Whether or not the unit uses the terminal-server idle timer and, if so, 
whether both the user and host must be idle before the unit disconnects 
the session.
TS Idle
The number of seconds that a terminal-server connection must be idle 
before the unit disconnects the session.
Parameter
Specifies
Max Call Duration
Maximum duration (in minutes) of an established session for an 
incoming call. The connection is checked once per minute, so the 
actual time of the call is slightly longer (usually less than a minute 
longer) than the actual time you set.
Preempt
Number of idle seconds the MAX unit waits before using one of the 
channels of an idle link for a new call.