Lucent Technologies 6000 User Manual

Page of 586
Configuring Individual WAN Connections
Configuring PPP connections
MAX 6000/3000 Network Configuration Guide
 4-43
Configuring PPP connections
A PPP connection is a temporary WAN connection brought up by a remote device dialing into 
the MAX. It is the most common type of WAN connection, and can be configured in a local 
Connection profile or in RADIUS. The next sections contain examples of both types of 
configuration.
A PPP connections can be one of the following types:
PPP—A single-channel connection to any remote device running PPP software.
Multilink PPP (MP)—A multilink connection to an MP-compliant device from any 
vendor.
MP with Bandwidth Allocation Control Protocol (MP with BACP)—An MP call that uses 
BACP to increase or decrease bandwidth on demand.
Multilink Protocol Plus (MP+)—A multilink connection, to another MAX unit that uses 
dynamic bandwidth allocation (DBA) to increase or decrease bandwidth on demand.
Note:
MP+ supersedes MPP.
A multilink connection begins by authenticating a base channel. If the connection allows 
additional bandwidth, the local or remote unit dials another link. For example, if a dial-in 
Lucent Pipeline unit has a single-channel session at 56 Kbps or 64 Kbps and multilink PPP is 
configured, a second call can combine the first B channel with the second for a transmission 
rate of 112 Kbps or 128 Kbps.
MAX units can be stacked to distribute the bandwidth required for connections across multiple 
units (as described in “Configuring a Combinet connection” on page 4-91).
Note:
If a connection configured for MP or MP+ fails to establish multiple channels, it falls 
back to a single-channel PPP session. In either case, you can use the PPP parameters as part of 
the connection negotiation. Use the MP, BACP, and MP+ settings in addition to the 
single-channel PPP settings. 
Example of a single-channel PPP connection
This section describes how to set the parameters used for establishing a single-channel PPP 
call. Following are the related parameters (shown with sample settings):
Ethernet
Answer
Encaps
PPP=Yes
PPP Options
Route IP=Yes
Route IPX=Yes
Route AppleTalk=Yes
Bridge=Yes
Recv Auth=Either
MRU=1524
LQM=No
LQM Min=600
LQM Max=600
Link Comp=Stac