MAX 6000/3000 Network Configuration Guide
Configuring Individual WAN Connections
Configuring POTS capability on the MAX 6000 and MAX 3000
Example of a Numbering Plan profile
With the following configuration, the MAX expects eleven digits for all phone numbers 
beginning with a 1, and seven digits otherwise. Callers do not need to press the # key after 
entering the phone number. 
System
Numbering Plan
NPprofile1 
Name=NPprofile1
Active=Yes
Dial Prefix=N/A
Number Digits=7 
System 
Numbering Plan
NPprofile2
Name=NPprofile2
Active=Yes
Dial Prefix=1
Number Digits=11
MAXDAX
MAXDAX routing provides increased flexibility in routing network-to-network calls. This 
release extends this flexibility to calls originated from POTS ports.
To use the MAXDAX functionality for POTS calls, proceed as follows:
1
Assign channel group numbers to each channel that can be used for an outgoing call. For 
example:
Net/T1
Line Config
Line Config profile
Line 1
Net2Net ChanGroup ID
Ch 1=Switched
Ch 1 ChanGroup=2 
Ch 2=Switched
Ch 2 ChanGroup=4
2
Create a Call Routes profile that will match all calls to which you want to apply the 
MAXDAX functionality. Within this profile, define the appropriate destination channel 
group. For example:
System
Call Routes
CRprofile1
Name=CRprofile1
Active=Yes
Dst Chan Grp=2
System
Call Routes
CRprofile 2 
Name=CRprofile 2