Lucent Technologies 6000 User Manual

Page of 586
6-18
MAX 6000/3000 Network Configuration Guide
Configuring X.25
Setting up X.25 PAD sessions
X.25 PAD commands
This section describes the X.25 PAD user commands in two categories: those that manage calls 
from the PAD and those that affect X.3 profile and parameter settings for the local or remote 
PAD. In the following section, underlined letters in a command indicate the minimum string 
you have to enter to execute the command. Otherwise, commands in bold indicate the 
command you must enter to execute the command.
Commands for working with X.3 parameters and profiles
Following are the commands you can enter at the PAD prompt (*) to change an X.3 parameter 
setting or profile:
help
The help command displays a list of all X.25 PAD commands and syntaxes.
par?
 [param1[,param2,...]]
The Par? command displays the current values of the specified X.3 parameters. Or, if you 
specify no parameters, the command displays all current X.3 settings. For example:
par 2
prof 
[profile | ?]
The Prof command activates the X.3 profile (specified by the name shown in Table 6-3 on 
page 6-17)
, or if you use this command with the question mark (?) keyword, it displays the 
currently active profile followed by a list of available profiles. If you do not specify any 
arguments, the Prof command displays the currently active profile. For example:
prof infonet
set
 [param1:value1 [,param2:value2,...]]
The Set command sets one or more X.3 parameter values. For example:
set 1:0, 2:1
set?
 [param1:value1 [,param2:value2,...]]
The Set command is identical to the Set command, except that it displays all X.3 
parameter values after setting those specified on the command line.
tabs
 [LCL num1][REM num2][EXP num3]
The Tabs command sets and reads three nonstandard X.3 parameters that control tab 
expansion. You cannot access these parameters by the remote host using Q-bit packet PAD 
commands on the remote host. You must keep the PAD’s view of the current screen 
position accurate by setting EXP to 0 and LCL to the number of columns to which your 
terminal expands tabs. The settings enable the PAD to perform correct line folding, line 
deletion, and character deletion. The keywords function as follows:
DEFAULT 
(MINIMAL)
1:64, 2:1, 3:2, 4:0, 5:2, 6:5, 7:2, 8:0, 9:25, 10:72, 12:1, 13:5, 14:25, 
15:1, 16:8, 17:24, 18:18, 19:1, 20:0, 21:0, 22:0
NULL
1:0, 2:0, 3:0, 4:0, 5:0, 6:0, 7:0, 8:0, 9:0, 10:0, 12:0, 13:0, 14:0,15:0, 
16:0, 17:0, 18:0, 19:0, 20:0, 21:0, 22:0
Table 6-3. X.3 profiles  (continued)
X.3 profile
Contents