3-40
MAX 6000/3000 Network Configuration Guide
Configuring WAN Access
Configuring Host/BRI lines
InOctets and OutOctets show the number of bytes received by the answering device and 
transmitted by the calling device, respectively.
Note:
When an ISDN call disconnects in Germany, the ISDN switch sends call billing 
information to the call originator as part of the call tear-down process. For lines that use the 
German 1TR6 switch type, you can access ISDN call charges in the Ascend Enterprise MIB 
through SNMP management utilities.
Configuring Host/BRI lines
The Host/BRI module provides up to eight local ISDN BRI lines. A line terminating one of 
these local ISDN BRI lines might be a MAX unit (or any BRI device) on its own local Ethernet 
segment, or a Desktop video device with its own BRI line and built-in terminal adapter. When 
a MAX unit is connected to a Host/BRI line, it appears to be an AT&T switch.
Terminal Equipment devices on Host/BRI lines can call each other, making local 
net-to-Net/BRI calls. These local calls never go out to the WAN. They make use of the BRI 
bandwidth internally. They can also send and receive calls from the WAN. To the actual WAN 
switch, the MAX unit appears as the call’s end point. Routing to the Host/BRI line is handled 
internally. 
Note:
TAOS supports the European ISDN protocol for the eight-port Host/BRI card on MAX 
units that are configured as Network Terminating (NT) devices (see ISDN TE/NT Mode 
parameter in the MAX Reference). You can select this carrier switch type by setting the Switch 
Type parameter to NET3. 
To begin configuring Host/BRI lines, open a Host/BRI > Line Config profile and set the 
following parameters:
Then set the following parameters in each Line N subprofile:
Parameter
Specifies
Name
Descriptive name for the profile. You can configure several profiles in a 
Host/BRI sot and activate a profile when it is needed. (This parameter is 
optional. Functionality is not affected if you do not enter a value.)
Switch Type
Type of switch (carrier-specific) that provides the ISDN service for the 
MAX.
BRI Analog 
Encode
Support for user-selectable analog encoding for the BRI interface. If you 
are going to receive modem calls, you can set this parameter to specify 
the encoding type.
Parameter
Specifies
Enabled
Availability of the ISDN BRI line. If you set the Enabled parameter to 
No, the line is not available for use.
Dial Plan
Whether the module uses trunk groups or the extended dial plan to send 
and receive calls. (For details about dial plans, see “Configuring 