Lucent Technologies 6000 User Manual

Page of 586
Configuring WAN Access
Configuring Host/AIM6 and Host/Dual ports
MAX 6000/3000 Network Configuration Guide
 3-55
For detailed information about each parameter, see the MAX Reference.
Call Password and Flag Idle parameters
A call profile includes a Call Password and a Flag Idle parameter. (For the definition of call 
parameter specifies the password for outgoing AIM and BONDING calls. The Flag Idle 
parameter specifies the bit pattern that a dynamic call to an AIM port uses as the idle indicator. 
Select the Yes setting to specify the flag pattern or the No setting to specify the mark pattern. 
Both patterns include enough 1 bits to maintain clock synchronization with the remote unit. 
Both ends must use the same pattern. Receipt of the specified pattern indicates to the local unit 
that the remote unit is not sending data.
For detailed information about each parameter, see the MAX Reference.
Configuring an AIM call 
To configure an AIM call that uses dynamic bandwidth allocation to manage the call 
dynamically:
1
Open a Host/AIM6 (Host/Dual) > PortN Menu > Directory > call profile.
2
Set the Dial # to specify the remote device, and set Call Type to AIM.
3
Set Call Mgm to Dynamic.
Dyn Alg 
The algorithm to use for calculating Average Line Utilization (ALU) 
over the number of seconds specified by the Sec History parameter. 
Sec History
A time period, in seconds, that serves as the basis for calculating ALU.
Add Pers
T
he time, in seconds, for which the ALU must exceed the value 
specified for the (Host/AIM6 (Host/Dual) > PortN Menu > Directory > 
call profile > Target Util parameter before the unit adds bandwidth.
Sub Pers
The time, in seconds, for which the ALU must fall below the value 
specified for the (Host/AIM6 (Host/Dual), PortN Menu > Directory > 
call profile > Target Util parameter before the unit subtracts 
bandwidth.
Time PeriodN 
The submenu parameters for dividing each AIM call are:
Activ—Specifies a call management time period for an AIM call.
Beg Time— Specifies the start-time of a dynamic AIM call’s time 
period.
Min Ch Cnt—Specifies the minimum number of channels that can 
be established for a multilink call. 
MAX Ch Cnt—Specifies the maximum number of channels that 
can be allocated to a multilink connection.
Target Util—Specifies a percentage of line utilization to use as a 
threshold for determining when to add or subtract bandwidth.
Parameter
Specifies