Enterasys Networks CSX5500 User Guide

Page of 729
Central Site Remote Access Switch      343
C
ONFIGURING
 IPX
IPX Triggered RIP/SAP
C
ONFIGURATION
 E
LEMENTS
D
ATA
B
ASE
 T
IMER
 
This timer starts when an update response is received. While this timer is running, the routes 
learned from this router are still considered reachable, and advertised as such on other interfaces. 
When this timer expires, the routes are considered unreachable and advertised as such until the 
hold-down timer expires. Valid range for timer: 1 to 10,000 seconds; default: 180 seconds.
H
OLD
-D
OWN
 T
IMER
While this timer is running, unreachable routes are advertised on other interfaces. This timer starts 
when:
the database timer for the route expires
a formerly reachable route changes to unreachable in an incoming response
a  WAN  circuit  goes  down
When this timer expires, and the unreachability information is communicated to all the reachable 
WAN routers, this route is deleted. Valid range for timer: 1 to 10,000 seconds; default: 120 seconds.
R
ETRANSMISSION
 T
IMER
This timer starts when an update request (or response) packet is sent out. If acknowledgment is not 
received by the time this timer expires, the packet is retransmitted. Valid range for timer: 1 to 10,000 
seconds; default: 5 seconds.
M
AXIMUM
 R
ETRANSMISSIONS
This provides a limit on the number of retransmission attempts for an update request (or response) 
packet. Maximum number supported: 10.
P
OLLING
 T
IMER
This is the frequency (in minutes) in which the next-hop WAN router is polled with update 
requests, once the maximum retransmission count threshold is exceeded. Polling takes place only 
when there is a physical connection; polling does not initiate its own connection. Valid range for 
timer: 1 to 10,000 seconds (165 minutes); default: 5 minutes.
O
VER
-
SUBSCRIPTION
 T
IMER
Over subscription is the situation in which there are more next-hop routers on the WAN that need 
updates than there are channels available. When a WAN circuit goes down, a delay (per the over-
subscription timer) is incorporated in marking the routes unreachable. This allows the calls to time-
multiplex over the limited channels. Valid range for timer: 1 to 10,000 seconds; default: 180 seconds.
T
RIGGERED
 RIP/SAP B
ACKGROUND
 I
NFORMATION
When there are a large number of remote destinations, the manual configuration of static routes 
and services over WAN circuits can pose a burden on system management. Yet running RIP/SAP 
could also be problematic; since these are broadcast protocols, periodic broadcasts may not be 
feasible due to cost and bandwidth considerations. Enabling the Triggered RIP/SAP feature allows 
the CyberSWITCH to send information on the WAN only when there has been an update to the 
database
 or a change in the reachability of a next-hop router.