Enterasys Networks CSX5500 User Guide

Page of 729
Central Site Remote Access Switch      383
C
ONFIGURING
 C
ALL
 C
ONTROL
CSM as a Call Control Manager
CSM 
AS
 
A
 C
ALL
 C
ONTROL
 M
ANAGER
This feature allows you to use the CSM for call control management only. This feature allows you 
to continue to use other authentication servers (e.g., RADIUS, ACE) yet still gain the benefits of 
CSM call control management.
C
ONFIGURING
 CSM 
FOR
 C
ALL
 C
ONTROL
U
SING
 CFGEDIT
1.
Select CSM as Call Control Manager from the Call Control Options menu. 
2.
The current status of the CSM Call Control Server will be displayed. Select 1 to toggle between 
enabled and disabled, and ensure an enabled setting.
3.
Select TCP port number if you wish to change this setting. Changes here will also appear on the 
CSM Authentication menu.
4.
Return to the Main Menu.
5.
For authentication, if you are using the On-node Device Table or Off-node Device Level Security
you are finished with the configuration of this feature. If you are using User Level Security, you 
may wish to adjust the Authentication Time-out and/or change the Call Control Failure 
banner. Continue with the following steps. 
6.
Select Security and then Network Login Information.
7.
Select Network Login General Configuration.
8.
Select Authentication Timeout. Follow on-screen instructions to adjust this value.
9.
Return to the Network Login Information Menu and select Network Login Banners.
10. Select the Call Control Failure Banner. Follow on-screen instructions to adjust this banner.
Note:
If you are using CSM as your authentication manager, you do not have to configure the call 
control option separately. This is only necessary when you are configuring another device 
for authentication, and wish to use CSM for call control only.
C
ONFIGURATION
 E
LEMENTS
S
TATUS
Allows you to enable or disable CSM for call control management.
TCP 
PORT
 
NUMBER
The TCP port number used by CSM. Note that you can assign a user-defined port number, but that 
the CSM TCP port number must be entered identically on both the CyberSWITCH and CSM.