Enterasys Networks CSX5500 User Guide

Page of 729
Central Site Remote Access Switch      469
V
ERIFYING
 S
YSTEM
 O
PTIONS
D Channel Callback
V
ERIFICATION
 
OF
 IP A
DDRESS
 P
OOL
As IP addresses are obtained from DHCP servers, they are placed into the system’s IP Address 
Pool. To verify the presence of these DHCP-obtained IP addresses, perform the following:
1.
Examine the address pool. Type:
ip addrpool
 <return>
2.
Look for addresses with an origin of DHCP. This verifies that IP addresses were obtained from 
a DHCP server, and the Proxy Client is working correctly. 
3.
If no “DHCP-obtained” addresses are present in the IP Address Pool, try the following
a.
Check the DHCP-related configuration for WAN and WAN (Direct Host) IP network 
interfaces which should have IP addresses obtained from DHCP servers for them. Use 
CFGEDIT, or use the
 
ipnetif
 command from Manage Mode. Correct if necessary.
b.
Make sure that the LAN port to reach the DHCP server on for the interface is correct.
c.
If the DHCP server is on a directly-connected LAN, you should be able to 
ping
 it 
successfully from the CyberSWITCH. If you cannot, check the LAN port IP configuration; 
make sure the DHCP server is operational. 
d. If the DHCP server is not on the directly-connected LAN, a DHCP Relay Agent must be. A 
relay agent is required in order to successfully forward DHCP packets to a DHCP server 
on a different sub-network.
e.
Assuming that a DHCP Relay Agent is present on the directly-connected LAN, you can 
attempt to
 ping
 the DHCP server. This may require the addition of IP static routes on both 
the CyberSWITCH and the DHCP server. These static routes are required for smooth 
operation of the DHCP protocol.
f.
If the DHCP server is not on a directly-connected LAN, another test may be performed. If 
at all feasible, place a DHCP client workstation on the same LAN with the server. See if this 
DHCP client can obtain an IP address from the DHCP server.
D C
HANNEL
 C
ALLBACK
1.
On the CyberSWITCH:
a.
Make sure you are using the Connection Services Manager (CSM) for device 
authentication.
b.
Make sure you have enabled D Channel callback.
2.
Define the calling devices on CSM. For each calling device configured through CSM, make sure 
you:
a.
Configure the device as an ISDN connection (under the device’s Telephone tab).
b.
Configure the telephone number to be used to call back to the calling device (under the 
device’s Telephone tab).