Philips TDA5051A User Manual

Page of 28
1999 May 31
15
Philips Semiconductors
Product specification
Home automation modem
TDA5051A
TEST INFORMATION
Fig.15  Test set-up for measuring demodulation delay.
handbook, full pagewidth
30 
Ω
µ
F
10 nF
XTAL
DATAIN
DATAOUT
td(dem)(su)
td(dem)(h)
DATAOUT
DATAIN
TXOUT/RXIN
OSCILLOSCOPE
Y1
TDA5051A
(to be tested)
pulse
generator
300 Hz
50%
Y2
TXOUT
RXIN
fosc
2
1
10
14
7
8
MGK838