18-80
August 2003
Access Navigator - Release 1.8
CLI Language Reference
CLI Command List
Example:
send ds1 9 payload f1in8 test
For the 1-in-8 and all-zeros patterns, the CLI will provide a progress message 
indicating the success (ok) or failure of the command, followed by a pattern detection 
message for each second of the test.
Message:
Waiting for pattern sync........ok.
   Testing line...
    08:18:23   Pattern Not Present
    08:18:24   Pattern Present
    08:18:25   Pattern Present
    08:18:26   Pattern Present
    08:18:27   Pattern Present
    08:18:28   Pattern Present
    08:18:29   Pattern Present
    08:18:30   Pattern Present
    08:18:31   Pattern Present
    08:18:32   Pattern Present
   Signaling done.
Description:
Item
Description
Time
Time is recorded in one-second intervals. Format is 24-hour 
clock in hours:minutes:seconds with colons to separate the digits, 
as in 08:30:45 and 15:22:10.
FBE
Number of Frame Bit Errors (4095 maximum) in one-second 
interval
BE
Number of Bit Errors (4095 maximum) in one-second interval
CRC
Number of Cyclical Redundancy Check errors (1023 maximum) 
in one-second interval
BPV/LCV
Number of Bi-Polar Violations and Line Code Violations 
(16,383 maximum) in one-second interval
Totals
Total number of errors for 10-second test interval
Error Rates
Total error rates measured during the 10-second test interval, 
expressed in scientific notation where "e" indicates a power of 
10. For example, 1 error per 1.544 megabits is 6.520000e-07. 
The maximum value is 2.700000e-03.