Carrier Access SNMP User Manual

Page of 180
12-14
9/24/01
Table 12-5: T1 Test LEDs for T1 Span 1 and 2
Table 12-6: V.35 Status LED
12.12  Fault Isolation Procedures
This section lists typical trouble symptoms that may occur while operating the Access Bank II - 
SNMP and suggests appropriate corrective actions to take. Fault symptoms are organized into three 
groups:
Control Panel LED indications (system, T1 or V.35 faults)
Back Plate LED indications (voice circuit faults)
Other fault indications
State
Meaning
GREEN
Normal operations. Trunk process-
ing, self test, and network loopback 
inactive. 
FLASHING GREEN
T1 Self Test local loopback passed.
RED
T1 Self Test local loopback failed 
due to one or more of the following 
conditions: T1 Loss of Signal, Out of 
Frame, Improper Line Code 
Received, ESF or BPV errors 
received.
YELLOW
Channels held in Trunk Processing 
for this T1 span.
FLASHING YELLOW
Network loopback active for this T1 
span.
State
Meaning
OFF
No T1 channels assigned to V.35 
port.
GREEN
CD (RLSD) and RTS leads active. T1 
channels assigned and operative.
FLASHING GREEN
V.35 in loopback to equipment.
RED
CD (RLSD) lead is inactive because 
assigned T1 is inoperative.
YELLOW
CD (RLSD) lead active. RTS lead 
inactive.
FLASHING YELLOW
V.35 in loopback to T1 line.