Hitachi CP-X2521WN User Manual

Page of 242
45
Item
Description
STANDBY MODE
Using ▲/▼ buttons switches the standby mode setting between 
NORMAL and SAVING. 
NORMAL Ù SAVING
When SAVING is selected, the power consumption in the standby 
mode is lowered with some functional restriction as below:
• When SAVING is selected, the RS-232C communication control 
except to turn the projector on and the network function are disabled 
while the projector is in the standby mode. If the COMMUNICATION 
TYPE in the COMMUNICATION menu is set to NETWORK 
BRIDGE, all of the RS-232C commands are disabled (
59).
• When SAVING is selected, STANDBY setting of AUDIO SOURCE 
(
46) is invalid, and no signal is output from AUDIO OUT port in 
the standby mode.
• When SAVING is selected, STANDBY setting of MONITOR OUT 
is invalid, and no signal is output from MONITOR OUT port in the 
standby mode.
MONITOR OUT
While the image signal from the input port chosen in step (1) is 
projected, the image signal from the input port selected in step (2) is 
output to MONITOR OUT port.
(1) Choose a picture input port using ▲/▼ buttons.
Choose STANDBY to select the picture  
output in the standby mode. 
(2)  Select one of the COMPUTER IN ports  
using ◄/► buttons. 
Select OFF to disable the MONITOR OUT  
port for the input port or standby mode  
chosen in the step (1).
• You cannot select COMPUTER IN2 for COMPUTER IN1, and vice 
versa.
• If you have changed the setting of STANDBY, it applies only to 
the current standby mode, NORMAL or SAVING, selected under 
STANDBY MODE, without changing the setting of the other mode. 
The factory settings are as follows:
- COMPUTER IN1 for the NORMAL mode of STANDBY MODE
- OFF for the SAVING mode of STANDBY MODE 
SETUP menu