12 
2011 June
700a-NA 
4-SPECIFICATIONS
IMPORTANT SAFEGUARD
5.  Tape Width
 
36mm [1 1/2 inch] minimum to 48mm [2 inch] maximum
4.  Tape
 
Scotch
®
 pressure-sensitive fi lm box sealing tapes.
3.  Operating Conditions
 
Use in dry, relatively clean environments at 5
o
 C to 50
o
 C [40
o
 F to 120
o
 F]  with clean, dry boxes.
 
Note:  
Machine should not be washed or subjected to conditions causing moisture condensation on 
  
components.
• 
 
To reduce the risk associated with fire 
   and explosion hazards:
  
Do not operate this equipment in poten- 
 
 tially 
fl ammable or explosive environments.
WARNING
1.  Power Requirements:
 
 
 
Electrical – 120 VAC, 60 Hz, 3.25 A 
 
Pneumatic – 6.5 bar gauge pressure [95 PSIG], 2.5 SCFM
 
 
    75 liter/minute @ 21° C., 1.01 bar maximum at maximum cycle rate.
 
 
    A pressure regulator/fi lter is included.
 
The machine is equipped with two 1/6 HP gearmotors and comes with an 2.4 m [8 foot] standard neoprene 
covered power cord and a grounded plug. Contact your 3M Representative for power requirements not listed 
above. Contact your 3M Representative for power requirements not listed above.
2.  Operating Rate:
 
Belt speed is 0.5m/s [100 F.P.M.]